Dry Bulb RH Controller

REQUEST CALLBACK

Dry Bulb RH Controller
Ask for Price

Thanks for Contacting Us.

Product Price :Get Latest Price

Product Details:
Minimum Order Quantity1 Piece
DimensionStandard

RHC301,a relative-humidity (RH) controller that uses wet and dry bulb temperatures to measure and display RH. A superior version of RHC201, it can apply a maximum or minimum function on RH as well as calculate dew point temperature. It receives two 4 - 20 mA or RTD inputs for wet and dry bulb temperatures within the range of -20 to 100 °C. The RH controller has a large two-color triple LED display to indicate a large variety of parameters. The upper display can indicate the calculated RH, peak RH (maximum) or valley RH (minimum). The middle can indicate dry bulb temperature or setpoint, while the lower can indicate wet bulb temperature, dew point temperature or the difference between dry and wet bulb temperatures. 15 additional LEDs indicate relay status, the process or measured value displayed, temperature units used (Celsius or Fahrenheit) and communication status. Operators program up to 4 setpoints easily via membrane buttons on the front of RHC301. The controller has an accuracy of ± 2 RH with a Class A Pt100 RTD and ± 0.5 RH for linear input. RHC301’s electromagnetic relays trigger humidification (heating), dehumidification (cooling), or any of six alarms - full-scale high and low, deviation high and low, inband and outband. Relays can be assigned to RH, Tdry, Twet, Tdew, Tdiff, water alarm or sensor fail. It transmits two isolated output signals which can be RH, Tdry, Twet, Tdew or Tdiff to other devices such as a Programmable Logic Controller (PLC) or Solid-State Relay (SSR). Signal isolation protects your devices and machines downstream of our instruments from damaging fluctuations in the input signal. RHC301 is conventionally an ON-OFF controller that outputs a discrete signal, but can also be used in Time-Proportioning Mode which turns the actuator on and off for periods proportional to the desired control effort, to emulate a continuous actuator that can generate a control effort between 0 and 100%. By including input terminals in the excitation loop, RHC301 provides a 24 V DC power supply for two-wire 4-20 transmitters.


Specifications

  • 2 x 4 - 20 mA or RTD inputs for dry and wet temperatures
  • Max, Min functions for RH
  • 2 or 4 setpoints for RH / Tdry / Twet / Tdew / Tdiff / Water alarm / Sensor fail
  • 85 - 265 V AC or 20 - 35 V DC supply
  • 24 V DC transmitter supply
  • RS485/MODBUS RTU
  • 2 x Isolated 0/4 - 20 mA or 0 - 10 V DC retransmission outputs corresponding to RH / Tdry /Twet / Tdew / Tdiff
  • Water alarm annunciator
  • Dew point temperature

 



Additional Information:

  • Item Code: RHC301
Yes! I am Interested

View PDF

Humidity and Temperature Controller

REQUEST CALLBACK

Humidity and Temperature Controller
Ask for Price

Thanks for Contacting Us.

Product Price :Get Latest Price

Product Details:
TypeAutomatic
Usagefor humidity / temperature control

  • Our Humidity and Temperature Controller, HTC96 is a ON-OFF controller designed for relative humidity & temperature control applications with a humidity range from 0 to 100% RH and a temperature range of -20 to 100° C. 
  • It receives input from Radix's SHT40(duct-mount) RH+T sensors and SHT20, SHT30 (wall-mount) which must be ordered separately and may be placed up to 50 meters from the unit. .
  • Operators program up to 2 set points via membrane buttons on the front of HTC96. 
  • This controller has an accuracy of ± 2% RH and ± 0.3° C. HTC96's electromagnetic relays trigger full-scale Hi and Lo alarms. 
  • It transmits one isolated output signal (either temperature or humidity) to other devices such as a Programmable Logic Controller (PLC) or Solid-State Relay (SSR). 
  • signal isolation protects your devices and machines downstream of our instruments from damaging fluctuations in the input signal. 
  • Our Humidity / Temperature Controller features Radix's proprietary sensor-break indication technology.

Specifications:

  • RH and T inputs from sensors
  • Accuracy: ± 2% RH, ± 0.3° C
  • Up to 2 set points for temperature and humidity
  • Isolated retransmission output for temperature and humidity
  • 85 - 265 V AC SMPS
  • User programmable
  • Sensor-break indication


Additional Information:

  • Item Code: HTC96
Yes! I am Interested

View PDF

Humidity and Temperature Controllers

REQUEST CALLBACK

Humidity and Temperature Controllers
Ask for Price

Thanks for Contacting Us.

Product Price :Get Latest Price

Product Details:
Minimum Order Quantity1 Piece
Model NumberHX96A
BrandRadix

  • Temperature Indicator and Controller, HX96A is a ON-OFF controller designed for relative humidity and temperature control applications with a humidity range from 0 to 100% RH and a temperature range of -20 to 100 °C. 
  • It receives input from Radix's SHT40(duct-mount) RH+T sensors and SHT20, SHT30 (wall-mount) which must be ordered separately and may be placed up to 50 meters from the unit HX96A features a two-color dual LED display; the upper indicates relative humidity and the lower, temperature while eight additional LEDs indicate communication status and the status of each relay. Operators program up to 4 set points via membrane buttons on the front of HX96A. 
  • This controller has an accuracy of ±2% RH and ± 0.3° C. HX96A's 4 electromagnetic relays trigger heating, cooling and full-scale Hi and Lo alarms.
  •  It transmits 2 isolated current or voltage output signals (either temperature or humidity) to other devices such as a Programmable Logic Controller (PLC) or Solid-State Relay (SSR). 
  • Signal isolation protects your devices and machines downstream of our instruments from damaging fluctuations in the input signal. 
  • This product features Radix's proprietary sensor-break indication technology.

Specifications:
  • Input: RH and T signals from sensor
  • Accuracy: ± 2% RH, ± 0.3 °C
  • 2 x isolated current or voltage outputs corresponding to T and/or RH
  • Up to 4 set points corresponding to T or RH
  • Sensor break indication
  • 85-265 V AC SMPS or 20-35 V DC supply
  • RS485/MODBUS RTU


Additional Information:

  • Item Code: HX96A
Yes! I am Interested

Humidity and Temperature Indicator

REQUEST CALLBACK

Humidity and Temperature Indicator
Ask for Price

Thanks for Contacting Us.

Product Price :Get Latest Price

Product Details:
Minimum Order Quantity1 Piece
DimensionStandard

HT20, a Relative Humidity Transmitter with a range from 0 to 100% RH and a temperature range of -20 to 100 °C. It receives input from Radix's SHT20, SHT30 ( wall-mount ) and SHT40(duct-mount) RH+T sensors which must be ordered separately and may be placed up to 50 meters from the unit. HT20 features a two-color dual LED display; the lower indicates the temperature & the upper is for relative humidity. This RH+T indicator is accurate to within 2% for humidity and within 0.3° C for temperature. HT20 transmits an isolated current (4-20 mA) or voltage (0-10 V DC) output signal to other devices such as a Programmable Logic Controller (PLC) or Solid-State Relay (SSR). Signal isolation protects your devices and machines downstream of our instruments from damaging fluctuations in the input signal. This product features Radix's proprietary sensor-break indication technology.

Specifications:
  • Input: RH and T signals from sensor
  • Accuracy: ± 2% RH, ± 0.3° C
  • User programmable
  • 85~265 V AC SMPS
  • Isolated retransmission output corresponding to either temperature or humidity
  • Sensor break indication


Additional Information:

  • Item Code: HT20
Yes! I am Interested

View PDF

Humidity Controllers

REQUEST CALLBACK

Humidity Controllers
Ask for Price

Thanks for Contacting Us.

Product Price :Get Latest Price

Product Details:
Minimum Order Quantity1 Piece
BrandRadix
DimensionStandard

RHC 201 is a Humidity Controllers that uses wet and dry bulb temperatures to measure and display RH. It receives two 4 - 20 mA or RTD inputs for wet & dry bulb temperatures within the range of -20 to 100 °C. A large two-color LED dual-display on the front of the RH controller indicates calculated RH in the upper display and in the lower either of the set point, Tdry, Twet or the difference between the two bulb temperatures. 6 additional LEDs indicate the status of each relay and the parameter in the lower display. Operators program up to 2 set points easily via membrane buttons on the front of RHC201. The controller has an accuracy of ± 2 RH with a Class A Pt100 RTD and ± 0.5 RH for linear input. RHC201’s electromagnetic relays trigger humidification (heating), dehumidification (cooling), or any of six alarms - full-scale high and low, deviation high and low, in band and out band.

Relays can be assigned to RH or Tdry. It transmits two isolated output signals to other devices such as a Programmable Logic Controller (PLC) or Solid-State Relay (SSR). Signal isolation protects your devices and machines downstream of our instruments from damaging fluctuations in the input signal. RHC201 is conventionally an ON-OFF controller that outputs a discrete signal, but can also be used in Time - Proportioning Mode which turns the actuator on and off for periods proportional to the desired control effort, to emulate a continuous actuator that can generate a control effort between 0 and 100%. By including input terminals in the excitation loop, RHC201 provides a 24V DC power supply for two-wire 4-20 transmitters.

Specifications:

  • 2 x 4-20 mA or RTD inputs for dry and wet temperatures
  • Accuracy: ± 2 RH
  • 2 set points for RH and dry bulb temperature
  • Isolated 0/4-20 mA or 0-10 V DC retransmission outputs corresponding to RH
  • 24 V DC transmitter supply
  • RS485/MOD BUS RTU


Additional Information:

  • Item Code: RHC201
Yes! I am Interested

View PDF

Clean Room Indicator

REQUEST CALLBACK

Clean Room Indicator
Ask for Price

Thanks for Contacting Us.

Product Price :Get Latest Price

Product Details:
Minimum Order Quantity1 Piece
DimensionStandard
BrandRadix

  1. RADIX offers a state-of-the-art technology solution for Relative Humidity, Temperature and Differential Pressure monitoring especially used for Clean Room applications.
  2.  Available in different categories as per costumer's requirement, such as LED, LCD and Real time clock display.
Specification
  • Microcontroller based
  • RH, Temperature & DP measurement
  • Software programmable channel ranges, units & input types
  • User programmable for 1,2 or 3 channel measurement
  • 3-row, 0.8” (20.3 mm), large, bright LED display
  • 3 programmable Alarms with visual annunciation
  • 3 programmable Alarms with open collector outputs to
  • operate external relays
  • Real Time Clock with battery back-up
  • Software calibration for all 3 channels
  • Calibration history / schedule for validation
  • RS485/MODBUS RTU multidrop communication for PLC,
  • SCADA, etc.
  • 24 VDC or 85~265 VAC SMPS supply
  • Powerful, user-friendly SCADA available
  • FDA 21CFR Part11 compliant SCADA version also
  • Advanced digital RH+T sensor technology


Additional Information:

  • Item Code: HAWKEYE
Yes! I am Interested

Cost-Effective Programmable Controller

REQUEST CALLBACK

Cost-Effective Programmable Controller
Ask for Price

Thanks for Contacting Us.

Product Price :Get Latest Price

Product Details:
DimensionStandard
BrandRadix

  • EC48 is a cost-effective programmable temperature controller. It accepts J-type (Iron/Constantan) and K-type (Chromel/Alumel) thermocouples as well as Pt100 RTD inputs. 
  • A large LED dual-display on the front of the process controller shows the difference in values of the setpoint and process value while 2 additional LEDs indicate the status of each of the two relays.
  •  Buttons on the front of EC48 allow operators to easily program up to 2 setpoints for the process value.
  •  With an error of only 0.1% of the full-scale, this is a process controller of superior accuracy.
  •  Typically, readings have a maximum error of ± 1 °C. The controller has 2 electromagnetic relays that trigger heating or cooling. 
  • EC48 is conventionally an ON-OFF controller that outputs a discrete signal, but can also be used in Time-Proportioning Mode which turns the actuator on and off for periods proportional to the desired control effort, to emulate a continuous actuator that can generate a control effort between 0 and 100%. This product features Radix's proprietary sensor-break indication technology.
See less

J, K thermocouples and Pt100 RTD inputs
Up to 2 setpoints
Accuracy: ± 0.1% of full scale, typically ±1 °C
ON-OFF and Time Proportional Control
85 - 265 V AC SMPS power supply
Sensor break indication
Yes! I am Interested

RH-T Controller

REQUEST CALLBACK

RH-T Controller
Ask for Price

Thanks for Contacting Us.

Product Price :Get Latest Price

Product Details:
Minimum Order Quantity1 Piece
ModelHX96A
BrandRadix

  • HX96A is a ON-OFF controller designed for relative humidity and temperature control applications with a humidity range from 0 to 100% RH and a temperature range of -20 to 100 °C.It receives input from Radix's SHT30, SHT20 (wall-mount) and SHT40(duct-mount) RH+T sensors which must be ordered separately and may be placed up to 50 meters from the unit.
  •  HX96A features a two-color dual LED display; the upper indicates relative humidity and the lower, temperature while eight additional LEDs indicate the status of each relay and communication status. Operators program up to 4 setpoints via membrane buttons on the front of HX96A. This controller has an accuracy of ± 2% RH and ± 0.3 °C. HX96A's 4 electromagnetic relays trigger heating, cooling and full-scale Hi and Lo alarms.
  •  It transmits 2 isolated current or voltage output signals (either temperature or humidity) to other devices such as a Programmable Logic Controller (PLC) or Solid-State Relay (SSR). 
  • Signal isolation protects your devices and machines downstream of our instruments from damaging fluctuations in the input signal. This product features Radix's proprietary sensor-break indication technology.


Specifications:

  • RH and T inputs from sensors
  • Accuracy: ± 2% RH, ± 0.3 °C
  • Up to 4 setpoints corresponding to T or RH
  • 85 - 265 V AC SMPS or 20 - 35 V DC supply
  • 2 x isolated current or voltage outputs corresponding to T and/or RH
  • RS485/MODBUS RTU
  • Sensor break indication

 



    Additional Information:

    • Item Code: HX96-A
    Yes! I am Interested

    View PDF

    FLP Temperature Indicator

    REQUEST CALLBACK

    FLP Temperature Indicator
    Ask for Price

    Thanks for Contacting Us.

    Product Price :Get Latest Price

    Product Details:
    Minimum Order Quantity1 Piece
    BrandRadix
    ModelX96A

    • X96A, an ON-OFF controller housed in a heavy-duty enclosure certified flameproof for gas groups I, IIA & IIB with IP65 rating - completely dust proof and a good level of protection against water. 
    • This product is wall-mounted and designed for use in hazardous environments. It receives input from 8 types of thermocouples (B, E, J, K, N, R, S, T), Pt100, Cu53 as well as other 3-wire RTD sensors, 0 - 50 mV & 4-20 mA or 0 - 20 mA linear inputs. Group 1 contains 8 types of thermocouples (B, E, J, K, N, R, S, T), Pt100 RTDs and 0/4-20 mA and 0-50 mV linear inputs. Group 2 contains 11 types of thermocouples (B, D, C, E, G, J, K, N, R, S, T), Pt100 and Cu53 RTDs, 0/4-20 mA and 0-50 mV linear inputs. 
    • A large LED dual-display on the front of the controller shows the difference in values of the set point and process value while 10 additional LEDs indicate the state of each relay, set points and Auto/Manual status.
    •  Operators to easily program up to 4 set points via membrane buttons on the front of X96A. With an error of only 0.1% of the full-scale, this is a process controller of superior accuracy.
    • X96A's electromagnetic relays trigger heating, cooling or any of 6 types of alarms - full-scale high/low, deviation high/low, in band and out band.
    •  It also retransmits an isolated 0/4-20 mA or 0-10 V DC output signal to other devices such as a Programmable Logic Controller (PLC) or Solid-State Relay (SSR). Signal isolation protects your devices and machines downstream of our instruments from damaging fluctuations in the input signal. 
    • By including input terminals in the excitation loop, X96A provides power for 2-wire 4-20 mA transmitters.

    Specifications:
    • 2 x universal inputs
    • Up to 4 set points
    • 24 V DC transmitter supply
    • 2 x Isolated retransmission outputs
    • RS485 / MODBUS RTU
    • 85-265 V AC SMPS
    • ON-OFF control


    Additional Information:

    • Item Code: X96Agen
    Yes! I am Interested

    View PDF

    Manual Loader / Auto-Manual Station

    REQUEST CALLBACK

    Manual Loader / Auto-Manual Station
    Ask for Price

    Thanks for Contacting Us.

    Product Price :Get Latest Price

    Product Details:
    Minimum Order Quantity1 Piece
    DimensionStandard
    BrandRadix

    TC96 - Manual Loader/Auto-manual Station
    • TC96 is a mid-range programmable temperature controller; feature-rich and cost-effective at the same time.It receives input from 8 types of thermocouples (B, E, J, K, N, R, S, T), Pt100 3-wire RTD sensors and optionally, 0 - 10 V DC and 4/ 0 - 20 mA linear inputs.
    •  A large LED dual-display on the front of the temperature controller shows the difference in values of the setpoint and process value while 2 additional LEDs indicate the status of each of the two relays.
    •  Buttons on the front of TC96 allow operators to easily program up to 2 setpoints for the process value. With an error of only 0.1% of full-scale value, this is a temperature controller of superior accuracy.
    •  TC96's electromagnetic relays trigger heating, cooling or full-scale high and low alarms.
    •  It also retransmits an isolated output signal to other devices such as a Programmable Logic Controller (PLC) or Solid-State Relay (SSR). .
    • Signal isolation protects your devices and machines downstream of our instruments from damaging fluctuations in the input signal. 
    • TC96 is conventionally an ON-OFF controller that outputs a discrete signal, but can also be used in Time-Proportioning Mode which turns the actuator on and off for periods proportional to the desired control effort, to emulate a continuous actuator that can generate a control effort between 0 and 100%. 
    • This product features Radix's proprietary sensor-break indication technology.
    Specifications:

    • Manual Loader : type A, B or D
    • Auto/Manual station : type C
    • Isolated 4~20 mA output:85~265 V AC SMPS OR 20~35 V DC OR 24 V AC
    • Accuracy : ± 1% typical
    • Input : 4~20 mA, 0~1 K ohms
    • Input fail indication


    Additional Information:

    • Item Code: TC96
    Yes! I am Interested

    View PDF
     
    X


    Explore More Products

    Contact via E-mail
    Contact via SMS
    Radix Electrosystems Private Limited
    Mayuri Kulkarni (Sr. Engineer Technical Support)
    B-17, 1st Floor, Ghanshyam Industrial Estate Off Veera Desai Road, Andheri West,
    Mumbai - 400053, Maharashtra, India
    Call Us: 
    Call Response Rate: 52%
    Share Us :
    F G T L



    Home  |   About Us   |  Our Products  |  Site Map  |   Contact Us

    © Radix Electrosystems Private Limited. All Rights Reserved (Terms of Use)
    Developed and Managed by IndiaMART InterMESH Limited

    Radix Electrosystems Private Limited