Call 08048968342 87% Response Rate

Send Email

Sanitary RTD Sensor

Our range of products include radix rhf401 rtd, fermenter/vessel temp sensor, all ss, sanitary rtd sensor for pharma & cip/sip, radix rhf401, rhs600 sanitary rtd, high purity, cip/sip compliant and radix rhs600 rtd for pharma & dairy.

Radix RHF401 RTD, Fermenter/Vessel Temp Sensor, All SS

Radix RHF401 RTD, Fermenter/Vessel Temp Sensor, All SS
  • Radix RHF401 RTD, Fermenter/Vessel Temp Sensor, All SS
  • Radix RHF401 RTD, Fermenter/Vessel Temp Sensor, All SS
  • Radix RHF401 RTD, Fermenter/Vessel Temp Sensor, All SS
  • Radix RHF401 RTD, Fermenter/Vessel Temp Sensor, All SS
Get Best Quote
Get Latest Price

Product Brochure

Product Details:
RTD Element MaterialPlatinum
AccuracyClass A
Sensor Connection Wiring4 Wire
Temperature Range-50 to 250 deg C
ApplicationPharmaceutical
Termination TypeTerminal Head Assembly
Cable Length3 m+
  • RTD type : Pt100, 3-wire/4-wire; Pt1000, 2-wire/3-wire
  • Accuracy : Class A/Class AA (1/3 DIN) to IEC 60751
  • No. of elements Simplex/Duplex
  • Sheath length (SL) : Upto 300 mm (11.8") below head. Contact sales for other lengths
  • Sheath material : SS316L
  • Tip rating : -50 to 250ºC (-58 to 482ºF)
  • Options : NABL calibration, Head mounted transmitter
  • Roughness value (Ra) ≤ 0.8 µm and ≤ 0.4 µm for non-wetted and wetted
  • SS304 terminal head and coupling nut 
  • EPDM sealing ring
  • Operating pressure 10 bar
  • Temperature range : Sensors tip -50 to 250°C (-58 to 482°F)
  • Polyamide cable gland, M20x1.5 (M)
  • Protection class, IP68 (NEMA 6P)
Yes! I am InterestedRequest A Callback

Sanitary RTD Sensor for Pharma & CIP/SIP, Radix RHF401

Sanitary RTD Sensor for Pharma & CIP/SIP, Radix RHF401
  • Sanitary RTD Sensor for Pharma & CIP/SIP, Radix RHF401
  • Sanitary RTD Sensor for Pharma & CIP/SIP, Radix RHF401
  • Sanitary RTD Sensor for Pharma & CIP/SIP, Radix RHF401
  • Sanitary RTD Sensor for Pharma & CIP/SIP, Radix RHF401
Get Best Quote
Get Latest Price

Product Brochure

Product Details:
RTD Element MaterialPlatinum
AccuracyClass A
Sensor Connection Wiring4 Wire
Temperature Range-50 to 250 deg C
ApplicationPharmaceutical
Termination TypeTerminal Head Assembly
Cable Length3 m+
  • RTD type : Pt100, 3-wire/4-wire; Pt1000, 2-wire/3-wire
  • Accuracy : Class A/Class AA (1/3 DIN) to IEC 60751
  • No. of elements Simplex/Duplex
  • Sheath length (SL) : Upto 300 mm (11.8") below head. Contact sales for other lengths
  • Sheath material : SS316L
  • Tip rating : -50 to 250ºC (-58 to 482ºF)
  • Options : NABL calibration, Head mounted transmitter
  • Roughness value (Ra) ≤ 0.8 µm and ≤ 0.4 µm for non-wetted and wetted
  • SS304 terminal head and coupling nut 
  • EPDM sealing ring
  • Operating pressure 10 bar
  • Temperature range : Sensors tip -50 to 250°C (-58 to 482°F)
  • Polyamide cable gland, M20x1.5 (M)
  • Protection class, IP68 (NEMA 6P)
Yes! I am InterestedRequest A Callback

RHS600 Sanitary RTD, High Purity, CIP/SIP Compliant

RHS600 Sanitary RTD, High Purity, CIP/SIP Compliant
  • RHS600 Sanitary RTD, High Purity, CIP/SIP Compliant
  • RHS600 Sanitary RTD, High Purity, CIP/SIP Compliant
  • RHS600 Sanitary RTD, High Purity, CIP/SIP Compliant
  • RHS600 Sanitary RTD, High Purity, CIP/SIP Compliant
Get Best Quote
Get Latest Price

Product Brochure

Product Details:
RTD Element MaterialPlatinum
AccuracyClass A
Sensor Connection Wiring4 Wire
ApplicationPharmaceutical
Termination TypeTerminal Head Assembly
Cable Length3 m+
  • RTD type : Pt100, 3-wire/4-wire; Pt1000, 3-wire/4-wire
  • No. of elements : Simplex/Duplex/Triplex
  • Accuracy : Class A / AA (1/3 DIN) to IEC 60751
  • Sheath material : SS316L
  • Tip rating : -50 to 250ºC (-58 to 482ºF)
  • Process connection : Triclover connection in ¹⁄ " (25 mm), ³⁄ " (25 mm), 1 ¹⁄ " (50.4 mm), 2" (64 mm) & 2.5" (77.5 mm) sizes
  • Options : a) NABL calibration b) Head mounted transmitterTriclover connection in ¹⁄ " (25 mm), ³⁄ " (25 mm), 1 ¹⁄ " (50.4 mm), 2" (64 mm) & 2.5" (77.5 mm) sizes
  • Operating pressure 10 bar
  • Roughness value (Ra) ≤ 0.8 μm and ≤ 0.4 μm for non-wetted and wetted parts respectively
  • CE certification
Yes! I am InterestedRequest A Callback

Radix RHS600 RTD for Pharma & Dairy

Radix RHS600 RTD for Pharma & Dairy
  • Radix RHS600 RTD for Pharma & Dairy
  • Radix RHS600 RTD for Pharma & Dairy
  • Radix RHS600 RTD for Pharma & Dairy
  • Radix RHS600 RTD for Pharma & Dairy
Get Best Quote
Get Latest Price

Product Brochure

Product Details:
RTD Element MaterialPlatinum
AccuracyClass A
Sensor Connection Wiring4 Wire
Temperature Range-50 to 250 deg C
ApplicationPharmaceutical
Termination TypeTerminal Head Assembly
Cable Length3 m+
  • RTD type : Pt100, 3-wire/4-wire; Pt1000, 3-wire/4-wire
  • No. of elements : Simplex/Duplex/Triplex
  • Accuracy : Class A / AA (1/3 DIN) to IEC 60751
  • Sheath material : SS316L
  • Tip rating : -50 to 250ºC (-58 to 482ºF)
  • Process connection : Triclover connection in ¹⁄ " (25 mm), ³⁄ " (25 mm), 1 ¹⁄ " (50.4 mm), 2" (64 mm) & 2.5" (77.5 mm) sizes
  • Options : a) NABL calibration b) Head mounted transmitterTriclover connection in ¹⁄ " (25 mm), ³⁄ " (25 mm), 1 ¹⁄ " (50.4 mm), 2" (64 mm) & 2.5" (77.5 mm) sizes
  • Operating pressure 10 bar
  • Roughness value (Ra) ≤ 0.8 μm and ≤ 0.4 μm for non-wetted and wetted parts respectively
  • CE certification